Home > Products > Heat Pump Space Heater > Commercial Heat Pump Space Heater > Evi -25℃ Commercial Heat Pump Space Heater

Evi -25℃ Commercial Heat Pump Space Heater

Evi -25℃ Commercial Heat Pump Space Heater
Evi -25℃ Commercial Heat Pump Space Heater
Evi -25℃ Commercial Heat Pump Space Heater

Evi -25℃ Commercial Heat Pump Space Heater

The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating uses the lower GWP refrigerant R410A and is mainly used in large commercial buildings such as schools, communities, hotels, shopping malls, etc. Indoor heating area is up to 920 m2 or even larger which can be customized. The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating can be customized to meet the needs of cooling, heating and domestic hot water supply.

Inquiry

 

Product Features:

The features of R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating are described as followed:
1. R410A Environmentally Friendly Refrigerant
The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating uses the environmentally friendly refrigerant R410A, which can produce heat at a low temperature of -25°C. The R410A refrigerant has a lower evaporation temperature, even at -25°C, and can still absorb heat at a lower evaporation temperature, resulting in a 20% increase in system heating capacity and 18% energy savings. The energy efficiency is about 1.6 times that of R22 refrigerant, and the core components of the R410A unit are thickened and upgraded, making the unit configuration more durable.

 

2. Copeland Compressor
The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating uses the famous Emerson brand compressor from the USA – Copeland – which is 12% more efficient than the most common compressors on the market. Under normal conditions, after the compressor has been turned off, the system will turn on again after 3 minutes by default, effectively extending the life of the compressor.

3. Low Noise Fan Blades
The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating is a large commercial unit, but its noise level is still very well controlled. In addition to the use of a fully inverter DC compressor to reduce noise, it uses a fan blade that also has a noise reducing effect.

4. Multiple Protection
The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating has multiple protection features such as high and low voltage protection, phase failure protection, overcurrent protection, exhaust temperature protection, water level protection, water flow protection, earth leakage protection and freeze protection to ensure safe and stable system operation.

Product Parameters:

R410A EVI On Off Commercial Heating Heat Pump Product Parameters
Model No.   NEAHDP-45.9TC/K NEAHDP-61.5TC/K NEAHDP-77.9TC/K NEAHDP-90.2TC/K
<Performance at Air 7℃, Water in/out 40/45℃>
Heating Capacity kW 45.90 61.50 77.90 90.20
Power Input kW 13.62 18.03 22.97 26.60
Rated Current A 27.28 36.11 46.01 53.28
C.O.P. W/W 3.37 3.41 3.39 3.39
Advised House Area m2 440~460 590~620 770~790 900~920
<Performance at Air -30℃, Water in/out 30/35℃>
Heating Capacity   22.60 30.30 38.30 44.40
Power Input   13.31 16.29 20.76 24.04
Rated Current  
C.O.P.   1.84 1.86 1.85 1.85
Advised House Area   210~230 290~310 370~390 430~450
<Performance at Air 35℃, Water in/out 12℃/7℃>
Cooling Capacity kW 41.77 55.97 70.89 82.08
Power Input kW 13.77 18.23 23.23 26.90
Rated Current A
E.E.R. W/W 3.033 3.069 3.051 3.051
Advised House Area m2 400~420 540~560 690~710 810~830
<System Parameters>
Working Temp. -25~45
Outlet Water Temp. 55~60 (Heating) / 7~12 (Cooling)
Power System V 380V/50Hz/3Ph
Control Panel   LCD Display
Compressor   Scroll
Refrigerant Type   R410A
Refrigerant Charge g
Condenser   High Efficiency Tank Heat Exchanger
Evaporator   Fin Heat Exchanger
Throttling Device   EEV
Defrost Function   with Intelligent Defrosting
Motor Quantity pcs 2 2 2 3
Motor Power Input W
Motor Speed rpm
Fan Direction   Horizontal
Water Connection mm DN40 DN50 DN65 DN65
Pressure Drop kPa ≤78 ≤80 ≤85 ≤88
Advised Water Flow m³/h 8.80 11.80 14.90 17.20
Waterproof Grade   IPX4
Electricity Protection  
Sound Pressure (10m) dB (A)
Sound Pressure (1m) dB (A) ≤68 ≤70 ≤72 ≤75
<Package Information>
Net Weight kg 380 485 582 665
Gross Weight kg 400 508 615 730
Net Size (W*D*H) mm 1507*857*1611 1850*1000*1950 2000*1100*2080 2200*1100*2080
Package Size (W*D*H) mm 1517*867*1741 1860*1010*2080 2010*1110*2210 2010*1110*2210
Loading per 20’GP pcs 6 6 5 5
Loading per 40’GP pcs 13 12 10 10
Loading per 40’HQ pcs 13 12 10 10
*More details please contact us.

 

Application and After-Sales Service:

1. Application
The R410A EVI On Off Commercial Heating Heat Pump for Commercial Building Heating is mainly used in hotels, schools, shopping malls, centrally heated communities and other places where central heating is required. There are already many installations in this field, both at home and abroad.

 

2. After-Sales Service
1) Certificate: CE & ROHS;
2) Warranty: the whole unit for 2 years, the compressor for 5 years, the titanium tube heat exchanger for 7 years; 1% free spare parts for the container order;
3) Support: Provide relevant documentation or video tutorials and real-time technical questions and answers to help customers solve problems quickly.

 

Spare parts, technological process, energy consumption, production line configuration, etc.

1. Accessories Bag
Instruction Manual*1, LCD Display*1, Rubber feet*4;

 

2. Production Capacity
The NOKKINGHAM factory is largely automated and is capable of producing more than 1000 heat pumps per day, while strict production processes and quality controls ensure timely delivery.

3. Transport Options
NOKKINGHAM has partnered with a number of shipping or courier companies and is able to offer a wide range of integrated transport solutions from door to port, door to door and more.